Brand Name : Consensic
Model Number : CAFS5008
Certification : PTC23041812701C-CN01
Place of Origin : WUXI
MOQ : Please contact us for details
Price : Offline conversation or face-to-face discussion
Payment Terms : L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments
Supply Ability : 999
Delivery Time : 3-7 work days
interface : G3/8Customizable
Flow range : 20/50/100/200/300slpm can be customized
Methods of Communication : 485/I2C optional
temperature : Medium temperature (-10~65)°C
Response time : 20ms optional
Overall material : Aluminum alloy (stainless steel optional)
This product is recommended for horizontal installation, though it can be installed vertically if site conditions are limited. Ensure that the arrow on the base indicates the direction of flow. Connect the media to the inlet and outlet ports accordingly.
Inspect the Flowmeter:
Prepare the Pipes:
Install the Flowmeter:
Follow these steps for proper installation:
Ensure Measurement Accuracy:
Sealing Material:
Connect Power Cable:
Signal Line Connection:
Note: Ensure the airflow direction is consistent with the sensor’s airflow indication direction. Once the sensor lead line is connected correctly, turn on the power supply to start operation.
Pipe Cleanliness:
Fixed Parts:
Installation Stress:
Environmental Conditions:
Stable Medium Flow:
| Model | Latus Rectum | Joggle | L | H | W | d | Specifications | 
|---|---|---|---|---|---|---|---|
| CAFS 5008 | 8 | 3/8’’ | 83 | 27 | 35 | 8 | 20 / 50 / 100 / 200 / 300 units (L/MIN) | 
CAFS5008 latus rectum 8 joggle 3/8’’ L 83 H 27 W 35 d 8 Performance Parameters
| Parameter | Unit | Remarks | 
|---|---|---|
| Flow range | 20/50/100/200/300 slpm | Customizable | 
| Power Supply Voltage | 8~24VDC, 50mA | Selectable | 
| Accuracy | ±1.5% FS | |
| Response time | 20 ms | Selectable | 
| Maximum pressure | 0.8 MPa | Customizable | 
| Communication mode | 485/I2C | Selectable | 
| Output method | Analog outputs of 1-5V | |
| Medium temperature | -10~65 ℃ | |
| Joggle | G3/8 | Customizable | 
| Levels of protection | IP40 | |
| Calibration method | Air, 0℃, and / 20℃ 101.325kPa | |
| Overall material | Aluminum alloys (stainless steel optional) | 
This guide outlines the correct installation and usage procedures for the CAFS5008 latus rectum 8 joggle 3/8’’ L 83 H 27 W 35 d 8 to ensure optimal performance and longevity.
|   | 
| CAFS5008 latus rectum 8 joggle 3/8’’ L 83 H 27 W 35 d 8 Images | 
 Flow Meter CAFS5012E Response Time 10,20,65,150 (Factory Default 65) Ms
                                                                                    
                        
                        
                        
                                                            Flow Meter CAFS5012E Response Time 10,20,65,150 (Factory Default 65) Ms
                                                    
                        
                     CAFS1000C levels of protection IP40 The overall material ABS
                                                                                    
                        
                        
                        
                                                            CAFS1000C levels of protection IP40 The overall material ABS
                                                    
                        
                     CAFS5032 latus rectum32 joggle PT1/4 The overall material stainless steel
                                                                                    
                        
                        
                        
                                                            CAFS5032 latus rectum32 joggle PT1/4 The overall material stainless steel
                                                    
                        
                     CMF9008 Nominal nominal diameter (mm) 8 joggle R3/8”customizable
                                                                                    
                        
                        
                        
                                                            CMF9008 Nominal nominal diameter (mm) 8 joggle R3/8”customizable
                                                    
                        
                     CAFS5012 communication mode RS485 Modbus joggle NTP 1/2”
                                                                                    
                        
                        
                        
                                                            CAFS5012 communication mode RS485 Modbus joggle NTP 1/2”
                                                    
                        
                     CAFS5006 latus rectum 6 joggle 1/4’’ L 83 83 27 W 35 d 6 specifications 10 / 20
                                                                                    
                        
                        
                        
                                                            CAFS5006 latus rectum 6 joggle 1/4’’ L 83 83 27 W 35 d 6 specifications 10 / 20
                                                    
                        
                     CAFS1000B Flow range10-800 Kg/h customizable repetitiveness
                                                                                    
                        
                        
                        
                                                            CAFS1000B Flow range10-800 Kg/h customizable repetitiveness
                                                    
                        
                     CAFS1000A Measure the channel cover O-ring seal Connect the plug
                                                                                    
                        
                        
                        
                                                            CAFS1000A Measure the channel cover O-ring seal Connect the plug
                                                    
                        
                     CMF9005 Nominal nominal diameter (mm) 5 Maximum flow specification selection
                                                                                    
                        
                        
                        
                                                            CMF9005 Nominal nominal diameter (mm) 5 Maximum flow specification selection
                                                    
                        
                     CAFS5012E Response Time 10,20,65,150 (Factory Default 65) Ms Customizable
                                                                                    
                        
                        
                        
                                                            CAFS5012E Response Time 10,20,65,150 (Factory Default 65) Ms Customizable